Hotel Audubon

9 N Main St. 

Ste. Genevieve, MO 63670

Inspection: September 27, 2023

  • Emergency lights are now working by the front door & on the upstairs stairwell.
  • All fire extinguishers were serviced in June 2023.
  • Evacuation plan and drills were performed in June 20, 2023.
  • All smoke & CO2 detectors were serviced & inspected.

Follow Up: not scheduled at this time. 

Triangle Inn

897 Ste Genevieve Dr

Ste. Genevieve, MO 63670

 

Inspection: June 22, 2023 Replace pressure relief value in hot H2O heater in the Laundry Room

Follow up: July 13, 2023 The pressure value has been replaced in the laundry room hot water heater.

Getaway St. Francois

7555 State Route Y

Bloomsdale, MO 63627

 

Inspection: April 11, 2023

  • DNR permitted waste water system is falling at various points in the three zones.
  • Waste water systems must be functioning properly at all times, DNR must be contacted & approve any repairs to the system.
  • Smoke detectors are not hardwired. Smoke detectors are required to be hardwired with battery backup.
  • Fire extinguishers have no inspection tags.
  • Fire extinguishers are required to be inspected annually.
  • No CO detector in main part of laundry room.
  • CO detector (hardwired with battery back up) required in rooms with gas appliances.
  • GFCI in the Ree cabin did not trip.
  • Three pronged receptacles must be properly grounded at all times.
  • The relief valve discharge pipe on the hotwater heater in laundry has too many elbows.
  • The relief valve discharge pipe also is directly connected to the 1 vat sink drain in laundry.
  • Relief valve discharge pipe shall be installed so as to drain by gravity flow & shall have no more than one elbow or be installed according to manufacturer’s specifiations.
  • Could not locate BTU’s on gas hotwater heater in laundry.
  • BTU rating of the temperature component of the T&P relief valve must be equal to or greater than the input BTU of the vessel it serves. This cold not be determined without identifying BTU’s for that heater.
  • Certification is required for units to DHSS that the units have been designed and erected in accordance with the 2002 edition of a national codes regarding life safety, structural, electrical, plumbing, mechanical, & architectural elements of the unit. Certification to these facts will be accepted by a professional engineer, architect or the general contractor responsible for the construction of the units be licensed.
  • Three vat sink in zone one of the laundry room is directly plumbed.
  • An indirect connection is required on a 3-vat sink.
  • No GFCI on electrical outlet behind hotwater heater in laundry.
  • Electrical outlets installed within five feet of a wet location are required to be fitted with a GFCI.
  • No leak test documentation for the liquid propane tank that serves laundry at main building.
  • No water sample logs maintained for well, no water sample was collected at time of inspection.

Main Street Inn

221 N Main St.

Ste. Genevieve, MO 63670

 

Inspection: June 20, 2023 – No violations today!

The Inn Ste. Gemme Beauvais

78 N Main St

Ste. Genevieve, MO 63670

 

Inspection: June 29, 2023 -Replace the T & P value on Carriage House hot water heater.

Fixed: August 28, 2023 – T & P relief value has been replaced on the Carriage House hot water heater.

Main St. Inn

221 N. Main St.

Ste. Genevieve, MO 63670

 

Inspection:

 

Follow-Up: 

Microtel Inn & Suites

21958 Hwy 32
Ste. Genevieve, MO 63670

 

Inspection: June 8,2023-Room #224 GFCI has a hot/neutral reversed. No current year evacuation plan drill has been performed.

Fixed: June 14, 2023-GFCI in room #224 is now properly grounded. Evacuation plan drill was performed by all employees on June 12, 2023